GE Worldwide Partner GE Consumer and Industrial - Electrical Distribution
Careers | Where to Buy | Contact Us | Online Store
 
GE Multilin
Home
Products
Services
Systems
Markets
Support
Contact Us
 
Product Resources
Ordering
Brochures
Manuals
Software
Drawings
Specifications
Support Documents
 
Related Tools
Online Store
Application Notes Tool
 
 
 
C90Plus Controller
Advanced automation & control and high accuracy digital fault recording. The C90Plus is a powerful logic controller specifically designed for the unique automation requirements of utilities, substation environments and industrial power systems.

More Info    Buy Now   
C60 Breaker Protection System
Integrated breaker monitoring and control for substation automation. The C60, a member of the UR Family, is a substation hardened controller that provides a complete integrated package for the protection, control, and monitoring or circuit breakers within a substation. The C60 provides fast and deterministic execution of programmable logic necessary for substation automation applications.

More Info    Buy Now   
C30 Controller System
Substation hardened, relay grade programmable logic controller. The C30, a member of the UR Family, is a digital IED designed to act as a substation hardened programmable logic controller that can also expand the I/O capability of protection devices and replace existing Sequence of Events (SOE) Recorders. The C30 provides fast and deterministic execution of programmable logic with I/O capabilities far above an average protection relay.

More Info    Buy Now   
N60 Network Stability and Synchrophasor Measurement System
Load shedding, remedial action and special protection schemes. The N60 Network Stability and Synchrophasor Measurement System, a member of the UR Family of protection relays, is a flexible device intended for the development of load shedding and special protection schemes.

More Info    Buy Now   
CIO Remote CAN I/O Module
    Remote CAN Bus Input/Output module for the 650 Family of relays. The remote CIO module provides additional input and output capabilities for the GE Multilin 650 family of relays.

More Info    Buy Now   
MIV II Voltage/Frequency Protection System
Three-phase and ground voltage protection relay. The MIV II, a member of the M II Family of protection relays provides voltage, frequency or voltage and frequency protection for a wide range of applications.

More Info    Buy Now   
MIV Voltage/Frequency Protection System
Three-phase and ground voltage protection relay. The MIV, a member of the M Family of protection relays provides voltage, frequency or voltage and frequency protection for a wide range of applications.

More Info    Buy Now   
MIW II Directional Power Protection System
Directional power and loss of field protection for generators. The MIW II, a member of the M II Family of protection relays provides directional power and loss of field protection for generators of any size.

More Info    Buy Now   
MIW Directional Power / Loss of Field
Directional power and loss of field protection for generators. The MIW, a member of the M Family of protection relays, provides directional power and loss of field protection for generators
of any size.

More Info    Buy Now   
MIN II Ground Protection System
Complete numerical ground directional protection. The MIN II, a member of the M II Family of protection relays, provides directional protection on distributed networks.

More Info    Buy Now   
MIN Digital Ground Protection
Complete numerical ground directional protection. The MIN, a member of the M Family of protection relays, provides directional protection on distributed networks.

More Info    Buy Now   
RRTD Remote RTD Module
Remote temperature monitoring of RTDs for metering and protection. The Remote RTD Module provides additional RTD temperature metering capabilities for the 369 Motor Protection System.

More Info    Buy Now   
DGT Distributed Generation Trip Control
The Multilin DGT Distributed Generation Trip Control solution enables fast and secure disconnect of renewable energy generators from the electrical power grid. The DGT solution delivers secure, swift and long distance transfer trip capabilities for enhanced safety, utmost reliability and maximum asset protection.

More Info    Buy Now   
DDFR Distributed Digital Fault Recorder
The DDFR™ is a Power System Fault Recorder that collects, archives and manages Disturbance and Fault information that is recorded by microprocessor-based protective relays distributed throughout your local power system.

More Info    Buy Now   
DBF Digital Breaker Failure
The DBF is a digital breaker failure relay that provides phase and ground backup protection if the primary circuit breaker fails to clear a system fault.

More Info    Buy Now   
DBT Digital Breaker Supervision
The DBT is a digital relay that supervises the integrity of the breaker's tripping and closing circuits. The relay checks the continuity of the coil regardless of the status of the breaker (open or closed).

More Info    Buy Now